Loading…

| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 11 May 2026 | Onalaska | No | 3System: 09 - Working And Living Conditions Sub-System: 092 - Working Conditions Component: 09209 - Electrical Cause: Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Electrical Installations Shall Be Such That: The Safety Of Passengers, Crew And Ship From Electrical Hazards Will Be Ensured. PSCO Observed Exposed Wiring On Low Location Lighting On Multiple Levels In Crew Stairway #4. 74 SOLAS 20-II-1/40.1.3 Due Date: 5/30/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 6/12/2026 12:00:00 AM Resolution Description: Vessel Provided Proof Via E-Mail Of Replacement End Caps For Low Location Lighting. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07105 - Fire Doors/Openings In Fire-Resisting Divisions Cause: Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Fire Doors In Main Vertical Zone Bulkheads, Galley Boundaries And Stairway Enclosures Shall Be Self-Closing And Be Capable Of Closing With An Angle Of Inclination Of Up To 3.5 Degrees Opposing Closure. PSCO Observed The Following Doors Do Not Latch Fully Closed: A60.11.04, A60.5.34. 74 SOLAS 20 II-2/9.4.1.1.5.1 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 5/11/2026 12:00:00 AM Resolution Description: Vsl Corrected Prior To Conclusion Of Exam. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07101 - Fire Prevention Structural Integrity Cause: Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Where The Contents And Use Of A Space Are Such That There Is A Doubt As To Its Classification For The Purpose Of This Regulation, Or Where It Is Possible To Assign Two Or More Classifications To A Space, It Shall Be Treated As A Space Within The Relevant Category Having The Most Stringent Boundary Requirements. PSCO Observed Flammable Liquids Stored In The Deck 5 Carpenter Workshops (Cat. 13), Which Is Prohibited Without Approved Storage Cabinets. 74 SOLAS 20 II-2/9.2.2.3.2.2 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 5/11/2026 12:00:00 AM Resolution Description: Corrected Prior To Conclusion Of The Exam. |
| Date | Type | Details |
|---|---|---|
| 10 Jan 2024 | Other | The cruise ship is another vessel that had to alter her course in the Red Sea due to geopolitical tensions in the area. She was scheduled to pass through Bab El-Mandeb as part of her journey from Jordan to Oman, but it was decided to sail towards Sharm El Sheikh at the southern end of the Sinai Peninsula, then to Ain Sukhna and Safaga in Egypt, ultimately set to disembark all its passengers in Aqaba, Jordan. |
| 13 Apr 2026 | Busan | No | 21 07199 FIRE SAFETY (Other (Fire Safety)) No 2 02138 STRUCTURAL CONDITIONS (Decks – Construction) No |
| 20 Nov 2025 | Fremantle | No | 11 14402 POLLUTION PREVENTION - MARPOL ANNEX IV (Sewage Treatment Plant) (08.05.2025) No |
| 20 Nov 2025 | Fremantle | No | 0 |
| 08 May 2025 | Vancouver | No | 11 14402 POLLUTION PREVENTION - MARPOL ANNEX IV (Sewage Treatment Plant) No |
| 14 Jul 2024 | Dubrovnik | No | 1Fire Doors/Openings In Fire-Resisting Divisions Not As Required |
| 14 Mar 2024 | Hong Kong | No | 0 |
| 06 Dec 2023 | Antalya | No | 0 |
| 06 Aug 2023 | Falmouth | No | 218409, Dangerous Areas, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 01218, Medical Certificate, Certificate & Documentation - Crew Certificates, 1000, Missing |
| 19 Dec 2022 | Salaverry | No | 0 |
| 16 Nov 2022 | Bonaire | No | 1Fire Doors/Openings In Fire-Resisting Divisions; Deficiency Rectified, |
| 27 Sep 2022 | Bordeaux | No | 0 |
| 01 Oct 2021 | Gazenica | No | 0 |